pentair pool pump error code

codes will appear from time to time. choice for a Variable Speed Pump. Very low pH and alkalinity levels over several years can strip the copper from a heat exchanger and wear the tube walls paper thin.Saltwater pools can also develop corrosion around fin welds, which could . Who Makes the Best Pool Equipment -Pentair, Hayward, Jandy or Off Brands? getting clogged and the pump is unable to prime. These codes are a great way to do a simple diagnostic to see what issues your pump is having. Varying Pentair heater models require different amounts of water flow. If it Speed 1 LED/button will select the first speed which is 750 RPM. The ERR HLS code means that your heaters high-limit switch is stuck open. Hi, I installed a brand new pump. I like the fact that it can down convert the voltage and be used at 120V as well as at 230V. At ePoolSupply and poolinfloor.com, we know our pool parts. Regular Unscented Bleach I started doing pool service when I was 16 years old back in 1988. Is that an overcurrent fault code? If adequate airflow via the blower is restored within 60 seconds after the problem message shows, the heater will resume normal performance. Replace it. Pentair pool heater troubleshooting guide, Pentair Heater Error Codes [Reasons + Solutions], Water Flow Rates For Different Pentair Models, 2 More Confused Error Codes Of Pentair Heater. I have not had the error since and the drive has been working great. Views: 44 Report Jimrahbe Mod Squad TFP Expert LifeTime Supporter Jul 7, 2014 28,282 Bedford, TX It is controlled by an Easytouch and also has an Intelliclor salt system. It does this at all speeds not just one on setting. To get rid of this error message, youll need to make sure theres enough water flowing. Run the filter pump for a few minutes after turning on the heater for the first time or after a long period of time off to clear all air from the system. These error code explanations will give you some guidance for resolving the most common Pentair pool heater problems: NOTE: Any troubleshooting that involves electrical work, or opening the heat pump, should be done by a professional, What it means: temperature sensordetecting water above 107 degrees, What it means: temperature sensordetecting water below 40 degrees, What it means:the units low-pressure switch senses that water flow is open or low, What it means: remote inputs of Pool AND Spa are being triggered, What it means: water thermistor circuit is shorted, What it means: water thermistor circuit isopen/receiving constant power, What it means: defrostthermistor circuit isshorted, What it means: defrostthermistoris open; power is being interrupted, What it means:the 24 VAC supply voltage to the heat pump circuit board is low. I am new to the Forum but have loved the advice and guidance I have received through here for the last two years. This is especially useful in the afternoon when your houses cooling needs are highest and its cooling efficiency is lowest. You should be able to press the start/stop button to start up the pump. I put my voltage meter on the pump's load 1 and load two and it only read 118V. 0F Absolute AC Under-Voltage Detected: This indicates that the supply voltage has dropped below the operating range of 99v. See "HP Indicator" LPIndicator ISSUE The refrigerant system's low-pressure switch is showing as open. An ignition failure can be caused by a variety of heater components. So, if you. When the heater doesnt have sufficient air flowing through, the airflow switch trips. ERR SFS Error Code 7. When your heaters ignition control module fails to fire up the heater, this error code will be on display. It Hi, I have an error code on my Pentair variable speed pump. Anti-freezing: When active, the motor will run at 1000 rpm for 60 minutes. Went out to check on the pool before work and Monday and noticed that the pump was not running. 21 Communication Link between the HMI and Motor control has been lost: Check the jacketed wire on the backside of the keypad inside the drive top cover. Pentair Superflo VS Variable Speed Pump Err 02 code, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Maybe thats why you initially mistook it for an error code. To prevent the impeller from being clogged check your skimmer basket for debris and empty it when it becomes full. New Pentair pump giving error codes 0002 and 000F Hi, I recently replaced my pool motor and had my new VS SuperFlo working for about 1-2 weeks. Seek professional heat pump repair, Outside temperatures are too low to operate, Have pool heater tech check if the switch needs to be replaced, Check for additional error codes that are listed in this post. Note: The IntelliFlo's internal anti-freeze protection is disabled when connected to an IntelliTouch system. It could be a bad drive but that is not common. brand new pentair vs gives out code EOFF ,then shuts off . Please consider. Remove side access panel, two screws. Pentair Superflo VS Pump Error Codes Explained | ePoolSupply If purchased online will only receive a sixty-day limited warranty. I figure after looking at this dissassembled you could tell if it was impeded by some cruft in the impeller by trying to turn it manually. When the gas flow shuts off due to the faulty pressure switch or low flow rate, then your heater will face this issue. Learn more Shop Now Pentair - EC-011059 - IntelliFlo i1 Variable Speed Pool Pump - Limited Warranty $1,859.00 AFS stands for airflow switch. I'm guessing water is still frozen causing this? In ERR PS, the PS stands for the pressure switch. Now go to the breaker and turn the pump breaker off and then on again to reset the pump. Check for a voltage drop when the motor is running on high speed. Mine ended up being a faulty control board. Quieter These pumps barely make a whisper. So, if you have an older pool The buttons on your heaters front panel buttons will be disabled during this malfunction. Fault Codes - AquaCal Website The second method is to use a Allen Wrench and insert it into the back of the pump. Capacitor Replacement and Troubleshooting! Ensure that the 5 pin connector is properly plugged into the socket and that there is no damage to the cable. Clogged exhaust or air vents, a sooted exchanger, inadequate water flow, or a defective stack flue sensor are all possible reasons for this mistake. service professional to trouble shoot the pump. Thanks for the quick response. I also use the screwdriver to scrape away any debris that may be jammed in there. The Hole in One Basket: Connect a Cleaner at the Skimmer and Prevent Debris from Clogging the Pump! like this try this first before you replace the p. AboutPressCopyrightContact. . The FLO code indicates that the water flow to your heat pump has been halted by the filter pump. Disconnect the main power by turning off the breaker long enough for the keypad LEDs to turn off. Same as E05, clogged exhaust or air vents, a sooted exchanger, inadequate water flow, or a defective stack flue sensor are all possible reasons for this mistake. The time it takes a heat pump to heat a pool is determined by a few factors. Now go to the breaker and turn the pump breaker off and then on again to reset the pump. As an industry leader, we're proud of the innovative designs and exceptional efficiency our inground pool pumps can offer. The freon in your pool heating system should last roughly 15 years, or as long as the device itself. Hi, I recently replaced my pool motor and had my new VS SuperFlo working for about 1-2 weeks. Sta Rite Pool Heater Error Codes [13 Easy Solutions] - FireplaceHubs When you wire up this pump you basically have your two hot wires coming from the breaker, and you have a ground that screws to the case of the drive. I installed a new Superflo VS pump on my 16x36 inground pool. this may free the blockage. Inground Pool Pumps | Pentair ERR SFS signifies the stack flue sensor on your heater has reached a temperature of more than 480F. This could be caused by normal voltage variation and will clear itself. Create an account to follow your favorite communities and start taking part in conversations. RESOLUTION Edward in TX 22.4K subscribers Subscribe 35K views 2 years ago #capacitor #poolpump My Pentair pool. It will then begin to go into the priming mode and then start up. its quick and easy way. The cooling effectiveness of either a heat pump or an air conditioner can be improved by shading the exterior unit. Yup. Pentair heaters sometimes display codes R13 and R14. Variable speed pumps move water more efficiently at lower speeds, saving money and energy. Spin it completely around several times to make sure the blockage is cleared. The water temperature needs to fall below 135F for the high limit switch to close again and your heater to start working again. Looking at the case of the drive (where the ground screw attaches) you will notice that the seating surface for the ground wire is covered in powder coating. Pentair Pool Pump Not Working? Capacitor Replacement and My ended up smelling nicely burnt in the control/drive. Otherwise, after youve fixed the blower, youll have to reset the heater. Then turn it on and it works fine. All rights reserved. You should Pentair Heater Error Codes [Reasons + Solutions] 1. Pentair IntelliFlo3 VSF 3.0HP with I/O Board, Youtech - Home Services Digital Marketing Agency. The manual states that I should disassemble the pump and check the impeller and seal plate. Once the impeller spins freely the blockage has been What exactly should I be looking for? The method I always use is to remove the pump lid and pump basket, then I spin the impeller with a screwdriver. I happened to have a deep socket. There are two ways to clear the blockage. The Err 0002 can also indicate a wire is loose in the ERR AGS Error Code 6. Riptide Vacuum System Steering Knuckle Upgrade! Check out the chart below to see which range is best for your model. The control board may also be the culprit and checking it with a multimeter should confirm it. Pentair Minimax NT STD ERR message Postby Guru Thu 18 Feb, 2010 14:40 9 times out of 10 the "ERR" code is caused by a bad thermistor (temp sensor). After power is reconnected if one of these errors continues to reappear, the drive may need service. connected to the pool, make sure you are using an in-line leaf canister. great performance. Note: Only a member of this blog may post a comment. scheduled, flip open the top and see if there is an error code of some kind. E06 Error Code 2 More Confused Error Codes Of Pentair Heater 1. most common one is the Err 0002 and it is usually caused by the impeller COPYRIGHT 2023. Pentair Pool Heat Pumps Troubleshooting Guide ERR HLS Error Code 3. The Pentair SuperFlo Variable Speed pump is a great Press your desired speed button (from 1 to 4) for about 3 seconds to choose the preset pump speed to reset the speed. Speed Pump that you can install. It was scheduled to come on at 7am this morning and now its throwing the 001a error code. The Number One Source for All of Your Pool Care Needs. A malfunctioning ignitor, a busted control module, a clogged or damaged flame sensor, a bad thermal regulator, or defective AGS or AFS are the likely reasons. If the Err 0002 code is still on the screen, You are using an out of date browser. Effect 20 RPM increments by pressing and holding the down/up button to steadily decrease or increase the pump speed. Generally just warranty it and the new one works fine. Pentair pool heater error code E05 indicates that the stack flue sensor is open, as the exhaust temperature was determined to be above 176F. Thus, the pump gave me an error code of 0008. But like anything electronic running from software, error codes will appear from time to time.If you see that your SuperFlo VS is not running as scheduled, flip open the top and see if there is an error code of some kind. JavaScript is disabled. Spin it Then lost power last night for 8 hours. It is very reliable and will give you years of And in that case, the common error codes with your Pentair MasterTemp are ERR PS, ERR HLS, ERR AFS, ERR IGN, ERR AGS, ERR SFS, E01, E05, and E06. How to Fix an Err 0002 on a Pentair SuperFlo Vs Pump - Blogger Error Code AD0: Bad Keypad 6. Simply open the front door and look directly behind the control board. Pool Pump Information Guide - Pentair You must log in or register to reply here. Power off the unit and restart. Please consider. I then did each line separately and found out one wasn't connected to the double pull GFI breaker correctly. Call Us Nationwide: 1-800-741-9956 West:213-291-9276Southwest:480-719-4511 Midwest:312-229-0026 Northeast:631-223-7175 Southeast:239-247-5878 Trustpilot Menu Browse Heaters Back I took mine apart (quite a pain) and there was nothing of interest there. Press question mark to learn the rest of the keyboard shortcuts. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. The pump is brand new and never used. Want to lower your pool heating bills and make pool care easy? Pentair heater error code E06 is another error code related to the stack flue sensor. Benefits of a Pentair Variable Speed Pool Pump Higher Performance Consistent flow control for the highest energy saving and ultimate system performance. Worst company I have ever dealt with by the way.Hope this helps someone. Pentair Minimax NT STD ERR message - Swimming Pool Help The pump ran fine yesterday. The If you have a suction side cleaner connected to the pool, make sure you are using an in-line leaf canister. When you notice the Pentair heater error code R13, you dont need to do anything because its merely a part of the startup routine. I got a new one from Pentair. You are using an out of date browser. Sump Pump Troubleshooting FAQ | Pentair I have a Pentair Superflo with error code 0002, following - JustAnswer This is because, after 60 seconds of mistake, the heater will enter lockout mode. Skimmer and Prevent Debris from Clogging the Pump! It is probably a built-in failsafe so that the pump doesnt overheat and become damaged. I looked down and viewed my mistake of allowing part of the plastic sheet to cover the pool motor fan intake. The thermal fuse is usually sealed with wax. I've had an occasional bad drive out of the box. Press J to jump to the feed. The heat pumphas locked due to five HP(high-pressure) faults during one call for heating or cooling. : https://www.swimmingpoollearning.com/swimming-pool-care-ebook, https://www.youtube.com/playlist?list=PLsvsTjbpoT-dsZaZkJevqaCgR7Tfl2XzP, Swimming Pool Tips, Reviews & How To Video Index (List) Alphabetical order. Replace if it is bad. How to Fix a Pentair SuperFlo VS Pump Err Code 0002 It would self prime in about 1 minute and everything was happy. SuperFlo Pool Pump by Pentair Aquatic Systems is a direct replacement for the Hayward Super Pump Extremely quiet operation; Unionized fittings included (1-1/2 in. All looked okay. If you have a suction side cleaner For a better experience, please enable JavaScript in your browser before proceeding. Hello , This is an inactive thread. If you installed the pump yourself you have no warranty anyway so I don't see the harm. At this point you may want to call out a pool service professional to trouble shoot the pump. And does anyone have a possible idea as to what is happeneing? Possible causes could be loose or damaged wiring, poor wiring connections, wrong wire type, wrong wire gauge, or issues with the relay or breaker associated with the pump. There is either a white or yellow wire connected directly to the back of the board. Any suggestions? Spa Error Codes - The Big List - Leslie's I went and checked the pumped and the display screen said "Err 0021". Pentair vs superflow model350879.A error code A1. At this point you may want to call out a pool Troubleshoot the high-pressure issue causing the error. If the Err 0002 code is still on the screen, try the above steps one more time and reset the pump again. View the list of TradeGrade Products. The AFS being open will cause this error message to pop on your screen. The pump ran fine yesterday. A repository of Pentair stakeholder and customer information at your fingertips including white papers, case studies and product manuals, etc. You will get much more visibility by. Freeze protection is provided by selecting YES at the ON WITH FREEZE start/stop button to start up the pump. 12 Pentair Heater Error Codes, Their Meanings & Solutions 1. Pentair Minimax NT Heater Error Codes - INYOPools.com If Code ERR is shown on the LED display at any time, turn the heater off at the power switch and then turn the heater back on. When the temperature of the water going through the heat exchanger for the second time exceeds 140F, the Pentair pool heater error code AGS occurs. Ensure adequate flow rate of water. Any hacks for a remote controlled Black and Decker Pool yet? If the error has not cleared then proper troubleshooting will be required. It means that your heater is getting too hot and the high limit switch turns off the heater for safety. and pump basket do not have rips or tears which could allow debris to get Read our article on Pentair ignition failure to learn more. E05 Error Code 9. Error 0021 on Pentair Superflo VS 303Michael Jul 4, 2022 Pumps, Filters, and Plumbing 5 Pumps, Filters, and Plumbing Jul 27, 2022 303Michael Any hacks for a remote controlled Black and Decker Pool yet? So, if the pump is on, hit the start/stop button to 02 -Absolute Phase current limit exceeded*, 08 -Absolute Diode Bridge temperature limit exceeded*, 04 -Absolute Power Module temperature limit exceeded*, 06 -Absolute Power Factor Correction (PFC) temperature limit exceeded*. You should be able to press the start/stop button to start up the pump. try the above steps one more time and reset the pump again. one or two resets. Error Code R13: Startup Mode 4. Its like not insulating your houses loft if you dont utilize a sun cover. UGH. Pentair Heat Pump Error Codes | Pentair Pool Heater Troubleshooting *17,16, 02, 08, 04, 06, 09, 0A Internal Errors: These errors can occur based on operating conditions and the UL 60730 required self-diagnostic safety software. Using an extension cord or wiring to outlet is too light. Easy to replace--remove two wire connections from terminals, unscrew defective thermister, screw in new unit, reattach wires to terminals, open valves, check for leaks, turn on pump and check for leaks, turn on heater -- took 10 minutes, less next time. The heater does nothing--does not turn on and i do not hear any clicking or fan noise. My family and friends were all swimming this past weekend with no issues. internal slip and 2 in. we cater to all your pool and spa needs with the utmost customer assistance. Pentair Pool Heater Troubleshooting Guide - InTheSwim Pool Blog Heat pump troubleshooting guide for Pentair pool heaters. Pentair superflow vs Faults and Alarms If an alarm is triggered the drive's LCD screen will display the fault code text and the pump will stop. If you get really fine particle debris, you can insert a Disclaimer, if you chose to do this it is at your own risk. This was typically happening in quick clean mode. voltage and be used at 120V as well as at 230V. Gently turn it back in forth until the . I like the fact that it can down convert the You need to test each of the components to see if they are the culprit. If they do not clear after multiple restart attempts, the drive should undergo a hard power cycle. I do have pine needles that make it through the basket occasionally, so wondering if those are getting caught. It is probably a built-in If the blockage was removed the screen You will get much more visibility by. Especially, in order for a heating system to be ready for winter use, it must be serviced in the fall. Press the stop button the pump will stop. Error Codes Key for Pentair Superflo VS Pump These codes are a great way to do a simple diagnostic to see what issues your pump is having. To prevent the impeller from being clogged check your skimmer Pentair Mastertemp 250 Troubleshooting Guide [11 Easy Fixes] The problem was that it happened so quickly you couldn't see what the error was. So, if you have an older pool on a single 110V breaker the SuperFlo VS pump is pretty much the only Variable Speed Pump that you can install. Hello , This is an inactive thread. I have same code. I have an error code on my Pentair variable speed pump. It Save the speed you have chosen by pressing and holding the speed buttons to allocate that speed. There are a number of reasons why your blower can stop working. The most common one is the Err 0002 and it is usually caused by the impeller getting clogged and the pump is unable to prime. Make sure that the pump is on by ensuring that the LED power is on. It was never meant to be public, but looks like others are looking at this so i'll try to make it useful.I was having a problem with my pump where you could hear it reset itself for no reason. If the issue code remains after taking all of these steps, the stack flow sensor may need to be replaced. When the motor is stopped it is not drawing much current. Fixed Pentair pool heater showing E01 error - amazon.com Using its control panel, you can easily set and reset the 4 selectable preset speeds or set the pump speed to run at a certain speed. I installed a new Superflo VS pump on my 16x36 inground pool. I checked voltage at the pump and I am getting 230V consistently. I had pump running 24/7 due to freeze. Pentair VS Pump - Error Code 0021 | Trouble Free Pool Error Code E06: Stack Flue Sensor Is Shorted 3. external slip) The manual states that I should disassemble the pump and check the impeller and seal plate. Once the impeller spins freely the blockage has been cleared. Pool Pumps Inground Pool Pumps With the wide selection of inground pool pumps from Pentair, your perfect pool pump is waiting for you. It may not display this or other websites correctly. See page 14 Pump Disassembly for instructions for disassembling the pump. Check the fuel supply, the heat regulator, and any orifice blockages again. The screen will display an error code as Err and then display a number. There are two ways to clear the blockage. Energy & Cost Savings Slow and steady wins the race. The Pentair SuperFlo Variable Speed pump is a great choice for a Variable Speed Pump. Any new postings here are unlikely to be seen or responded to by other members. It will stay off until the filter pump timer is reset, providing the heat pump with the necessary water flow.

What Rights Do Residents Have With Regard To Food Choices, Articles P